Electric Actuated Ball Valve

Electric actuated ball valve
Torque is the rotational force an actuator generates to close a rotational valve. Electric actuators can generate this force by transmitting it to the output shaft and then the valve stem. When pressure is applied to the valve stem, the valve's orifice opens or closes.
What is electric ball valve?
Electric Ball Valves. Typically used for ON/OFF control of water, air, oil and other compatible media. Valworx electric ball valves use an electric actuator to open and close the valve. These valves are power-to-open and power-to-close. Valve positioner and fail close options are available.
What is a ball valve actuator?
Description. Actuated ball valves are rotating ball type pipe valves that come without manual turn handles to allow installation with an actuator. The valves are used together with an actuator device to automate valve opening and closing and therefore control plumbing fluid rates.
How do you choose an actuator for a ball valve?
How to Select an Actuator for Valve
- Move the valve closure member (disc, ball, or plug) to the desired position.
- Hold the valve closure member in the desired position. ...
- Seat the valve closure member with sufficient torque to provide the desired shutoff specification. ...
- Provide a failure mode in the event of system failure.
What is the difference between control valve and actuator?
The actuator is the next logical area of interest. The operation of a control valve involves positioning its movable part (the plug, ball or vane) relative to the stationary seat of the valve. The purpose of the valve actuator is to accurately locate the valve plug in a position dictated by the control signal.
Where are electric actuators used?
Electric actuators are utilized in materials handling for operations like servo presses and clamping and most commonly used in the packaging sector. Electric actuators are used in electronics and electronic assembly, robotics, machine tools and multiple industrial sectors.
What is the difference between motorized valve and solenoid valve?
Motorized ball valves are cylindrical valves that regulate fluid or gas flow through a pipe by opening and closing a disk-shaped valve attached to the center of a cylinder. The solenoid valve, on the other hand, uses electromagnetic coils to move fluid between two piping systems.
How does a pneumatic actuator work on a ball valve?
Double-Acting Pneumatic Actuated Ball Valves Double-acting uses air to move internal pistons (racks) in two directions, which rotates the actuator pinion 90°. The pinion is connected to the ball valve stem and opens or closes the ball valve as it rotates.
How does an electro pneumatic actuator work?
The electro-pneumatic action is a control system by the mean of air pressure for pipe organs, whereby air pressure, controlled by an electric current and operated by the keys of an organ console, opens and closes valves within wind chests, allowing the pipes to speak.
What is a spring return valve actuator?
What Is a Spring Return Actuator? A spring return (aka single) actuator provides power with the use of spring force. Air or liquid is dispersed in one direction to push or pull the piston. This action controls whether the valve will open or close.
How does a spring return work?
Also known as a single-acting valve, a spring return works by having a supply of air or liquid on only one side of the piston. When the media fills the piston, the valve opens or closes. Then, when the supply is cut off, a spring mechanism removes the media and reverses the valve position.
How do I choose an electrical actuator?
Selecting an electric actuator Start with the motion profile. This establishes the demands for velocity and time as well as force (or torque) and the required travel distance. This is also the place to determine the maximum stroke needed as well as maximum and minimum speed requirements. Then calculate the load.
How do I know my actuator size?
When sizing an actuator, first consider your valve's torque requirements. This includes: Break torque, or opening torque, refers to the force required to start moving a closed valve. Running torque, or mid-stroke torque, is the force required to maintain movement of the valve between the open and closed positions.
Which actuator is best for control valve?
Electric actuators – multi-turn – These types of valves are among the most common and the most dependable. They're capable of quickly operating some of the largest valves, and they're powered by a single or three-phased electric motor that drives a combination of level gears and spurs.
What are the three types of valve control?
There are three primary types of control valve trim: Snap Trim (also referred to as Quick-Opening trim) Nominal Trim (also referred to as Linear trim) Equal Percentage Trim.
What are the types of valve actuators?
There are 4 basic types of valve actuators: pneumatic actuators, hydraulic actuators, electro-hydraulic, and electric actuators.
What is a self actuated valve?
self actuated pressure control valve. Self-actuated pressure control valves serve to maintain an adjustable set-point pressure within certain levels in pipelines or vessels (tanks). They are self-actuating i.e. do not feature additional auxiliary energy such as pneumatic air or electricity to operate.
What are the advantages of actuators?
Electric actuators provide extremely accurate control and positioning. In addition, this type of actuator helps adapt machines to flexible processes and has a low operating cost. This means that an electric system is energy efficient and can provide you with cost savings in many cases.
What is another name for an actuator?
control | controller |
---|---|
instrument panel | knob |
lever | mechanism |
switch | brake |
device | governor |
What are examples of actuators?
Examples of actuators
- Comb drive.
- Digital micromirror device.
- Electric motor.
- Electroactive polymer.
- Hydraulic cylinder.
- Piezoelectric actuator.
- Pneumatic actuator.
- Screw jack.